Axial Fan > SC8022AB
SC8022AB
Frame: Aluminium alloy die-casting, surfaces is finished by black anti-corrosion treatment.
Impeller: Black plastic PBT UL94V-0
Operation Temperature/Humidity Range: (under unconcretionary state) -30℃ ~ +60℃ (temperature), 0% ~ 95% (himidity)
Protection: Impedance Protected
Withstand Voltage: AC 1,500V , 1 min at 0.5mA, 50/60 Hz
Insulation System: Design according to IEC61858 Grade B,
Protection Grade: Design according to IEC61858 Grade B,
Impeller: Black plastic PBT UL94V-0
Operation Temperature/Humidity Range: (under unconcretionary state) -30℃ ~ +60℃ (temperature), 0% ~ 95% (himidity)
Protection: Impedance Protected
Withstand Voltage: AC 1,500V , 1 min at 0.5mA, 50/60 Hz
Insulation System: Design according to IEC61858 Grade B,
Protection Grade: Design according to IEC61858 Grade B,

Technical Parameter

References are based on the frame dimension, which helps you to quickly select the best choice for your installation.
Example:
When your installation space is enough for dimention 120*120*38mm, please choose FJ1203
When you choose AC 220V, frame size 120x120x38mm, sleeve bearing, plug-in connection, please choose model FJ12032AST
We can customize your unconventional products.
Example:
When your installation space is enough for dimention 120*120*38mm, please choose FJ1203
When you choose AC 220V, frame size 120x120x38mm, sleeve bearing, plug-in connection, please choose model FJ12032AST
We can customize your unconventional products.

Frame
Aluminium alloy die-casting, surfaces is finished by black anti-corrosion treatment.
Impeller
Black plastic PBT UL94V-0
Operation Temperature/Humidity Range: (under unconcretionary state)
-30℃ ~ +60℃ (temperature), 0% ~ 95% (himidity)
Protection
Impedance Protected
Withstand Voltage
AC 1,500V , 1 min at 0.5mA, 50/60 Hz
Insulation System
Design according to IEC61858 Grade B,
Protection Grade
Design according to IEC61858 Grade B,
Aluminium alloy die-casting, surfaces is finished by black anti-corrosion treatment.
Impeller
Black plastic PBT UL94V-0
Operation Temperature/Humidity Range: (under unconcretionary state)
-30℃ ~ +60℃ (temperature), 0% ~ 95% (himidity)
Protection
Impedance Protected
Withstand Voltage
AC 1,500V , 1 min at 0.5mA, 50/60 Hz
Insulation System
Design according to IEC61858 Grade B,
Protection Grade
Design according to IEC61858 Grade B,


Type |
Motor |
Rated Voltage |
Frequency |
current |
Power |
Speed |
Max Air Flow |
Static Pressure |
Noise |
Curve |
Capacitor Motor |
|
V |
Hz |
(A) |
(W)+10%-20% |
(min-1) |
CFM |
m3/h |
(Pa) |
(dB) |
(μF) |
|||
SC8021AB |
M2S5601-SB |
115 |
50 |
0.12 |
10 |
2300 |
17 |
29 |
33 |
29 |
① |
----- |
60 |
0.10 |
9 |
2700 |
21 |
35 |
37 |
33 |
|||||
SC8021AB |
M2S5601-BB |
115 |
50 |
0.13 |
13 |
2400 |
18 |
31 |
42 |
30 |
② |
----- |
60 |
0.15 |
15 |
2900 |
22 |
38 |
45 |
34 |
|||||
SC8022AS |
M2E5601-SB |
230 |
50 |
0.07 |
13 |
2300 |
17 |
29 |
33 |
29 |
① |
----- |
60 |
0.06 |
11 |
2700 |
21 |
35 |
37 |
33 |
|||||
SC8022AB |
M2E5601-BB |
230 |
50 |
0.07 |
13 |
2400 |
18 |
31 |
42 |
30 |
② |
----- |
60 |
0.06 |
11 |
2900 |
22 |
38 |
45 |
34 |